Addressing of Delta PLC DVP SS/ES/EX
Digital Input | X0-X177 Octal System i.e. (X0 To X7,X20 to X27 ) |
Digital Output | Y0-Y177 Octal System i.e. (Y0 To Y7,Y20 to Y27 ) |
Analog Input | Need To Read Control Register using �From� Instruction |
Analog Output | Need To Write Control Register using �To� Instruction |
Timers | T0 to T127(T0 to T126 =TB 100ms Default) |
For Timers : Time Delay = Time Base * Preset | |
Time Done Bit : Tx | |
Where X is address of Timer used. |
Counters | General C0 to C111, C112 to C127 Retentive |
For Counter: Preset is number of Counts. | |
Counter Done Bit : Cx Present value of Counter :Cx | |
Where X is address of counter used. |
Integer | D0 to D599(D408 to D599 Retentive) |
Auxiliary Relay | M0 to M999 (M512 to M767 Retentive) |
Programming Software : WPLSoft2.20 |
Driver For Programming: Modbus Serial |
Driver For SCADA Communication : Modbus |